HV Test Sets
HV Testing Instruments Special Developments |
HV Test Sets for dielectric tests of 110 kV and higher voltage ratings electrical equipmentUIV-(230, 345, 395, 450, 500 кV) Test Sets are designed for dielectric tests with partial discharge measuring of 110 kV and higher voltage ratings in the power apparatus manufacturing industry and on site.Sets are designed for dielectric tests of equipment with an air external insulation. The complete Test Set includes:
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Characteristic | Value | |||||
| UIV-230 | UIV-345 | UIV-395 | UIV-450 | UIV-500 | ||
| Rated voltage* ,Ur., kV | 230 | 345 | 395 | 450 | 500 | |
| Rated power supply voltage, V | 380 | 380 | 380 | 380 | 380 | |
| Rated frequency, Hz | 50 | 50 | 50 | 50 | 50 | |
| Generated voltage range, kV | 25 - 230 | 35 - 345 | 40 - 400 | 40 - 450 | 50 - 500 | |
| Test voltage (50 Hz), kV | 245 | 375 | 420 | 475 | 525 | |
| Steady short-circuit current, not less, A | 0,3 | 0,3 | 0,3 | 0,3 | 0,3 | |
| Max. load capacitance at Ur for 5 min., pF | 2700 | 2000 | 1000 | 1000 | 1000 | |
| Max. load capacitance at Ur for 1 min., pF | 4000 | 4000 | 1900 | 2000 | 1500 | |
| Max. load power, not less, kVA | 50 | 125 | 92 | 125 | 100 | |
| Max. power consumption, no more, kVA | 40 | 40 | 40 | 40 | 60 | |
| Test voltage measuring error, % | 3,0 | 3,0 | 3,0 | 3,0 | 3,0 | |
| Stability of voltage reproducing in the range, % | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | |
| PD extinction voltage (Ue), kV | 90 | 200 | 200 | 200 | 260 | |
| PD intensity at extinction voltage (Ue), no more, pC | 5,0 | 5,0 | 5,0 | 5,0 | 5,0 | |
| SF6 overpressure, MPa (kgf/sm2) | 0,39 (3,9) | 0,39 (3,9) | 0,44 (4,4) | 0,39 (3,9) | 0,39 (3,9) | |
| Inbuilt h.v. capacitance, pF | 450 | 300 | 300 | 300 | 300 | |
| High-voltage block mass, kg | 800 | 800 | 900 | 1200 | 1500 | |
| Voltage regulator block mass, kg | 600 | 650 | 600 | 700 | 900 | |
Note: *At Customer option Set can be manufactured at another rated voltage.
![]() |
|
| UIV-450 kV set HV SF6 -block moving on test stand territory |
block slope changing mechanism allows promptly adapt set to cealing height |
|
![]() |
| MPU-2.16-01 control panel |
UIV-450 kV set voltage regulator block with control panel |
![]() |
Manual and automatic mode of operation. | ![]() |
16 digital inputs and outputs |
| Built-in digital voltmeter. | ![]() |
Adjustment of the measuring channels scale factors. | |
![]() |
Test procedure programming. | ![]() |
High EMC degree. |
![]() |
Switching of rate of HV change | ![]() |
Set current and voltage displaying during tests. |
![]() |
3 «True RMS» inputs. | ![]() |
Built-in stopwatch. |
![]() |
Printer port for test report printout. | ![]() |
High accuracy of the automatic HV setting. |
![]() |
Galvanic separation of the control and measuring circuits (1 kV). | ![]() |
Temperature monitoring of HV source. |
|