HV Test Sets


HV Testing Instruments


Special Developments

HV Test Sets for dielectric tests  of 110 kV and higher voltage ratings electrical equipment

UIV-(230, 345, 395, 450, 500 кV) Test Sets are designed for dielectric tests with partial discharge measuring of 110 kV and higher voltage  ratings in the power apparatus manufacturing industry and on site.

Sets are designed for dielectric tests of equipment with an air external insulation.
At Customer option additional "docking" modules can be included in the scope of set supply, which allow to use these sets for Gas(SF6)-insulated Switchgear (GIS) testing by "closed" (screened) scheme..  

The complete Test Set includes:

SF6-block:

  • IOG-(230 … 500 kV) test transformer;
  • HV divider (coupling  capacitor);
  • “Air/SF6“-bushing;
  • Wheeled SF6-block frame with device for block slope changing and fixing;
  • Docking modules (option).

Voltage regulator block:

  • Regulating transformer;
  • Control and switching cabinet;
  • Compensating reactor.
     

PDM 201 Partial Discharges measuring Instrument:

  • Portable computer (laptop);
  • Partial discharges characteristics meter (PDM 201));
  • Remote measuring unit (“RMU”);
  • High-frequency filter (HFF) - 2 pcs;
  • Calibrating partial discharges generator (CGPD);
  • Cable set.

MPU-2.16-01 control panel

Working table, operator's chair

Ladder for installation

Cable set with lengthes not less than 10 m

VA 11 digital peak voltmeter

Certification and operational documentation:

  • Operation manual;
  • Logbook;
  • Primary qualification test program;
  • Primary qualification test report;
  • FSUE "D.I. Mendeleev VNIIM" set certificate;
  • FSUE "D.I. Mendeleev VNIIM" certificate for HV capacitive divider calibration;
  • FSUE "D.I. Mendeleev VNIIM" certificate for  PDM 201  instrument calibration;
  • VSUE "TEST Sankt-Peterburg" certificate for  VA 11  digital peak voltmeter calibration.

 

Sets allow to carry out tests in premises with limited floor space and ceiling height. High voltage SF6-block is easy move on testing ground of stand (see photo); block slope changing mechanism allows promptly adapt set to cealing height. ((see animation)

Basic specifications of sets are shown in table:

 
 Characteristic Value
UIV-230 UIV-345 UIV-395 UIV-450 UIV-500
Rated voltage* ,Ur., kV 230 345 395 450 500
Rated power supply voltage, V 380 380 380 380 380
Rated frequency, Hz 50 50 50 50 50
Generated voltage range, kV 25 - 230 35 - 345 40 - 400 40 - 450 50 - 500
Test voltage (50 Hz), kV 245 375 420 475 525
Steady short-circuit current, not less, A 0,3 0,3 0,3 0,3 0,3
Max. load capacitance at Ur for 5 min., pF 2700 2000 1000 1000 1000
Max. load capacitance at Ur for 1 min., pF 4000 4000 1900 2000 1500
Max. load power, not less, kVA 50 125 92 125 100
Max. power consumption, no more, kVA 40 40 40 40 60
Test voltage measuring error, % 3,0 3,0 3,0 3,0 3,0
Stability of voltage reproducing in the range, % 1,0 1,0 1,0 1,0 1,0
PD extinction voltage (Ue), kV 90 200 200 200 260
PD intensity at extinction voltage (Ue), no more, pC 5,0 5,0 5,0 5,0 5,0
SF6 overpressure, MPa (kgf/sm2) 0,39 (3,9) 0,39 (3,9) 0,44 (4,4) 0,39 (3,9) 0,39 (3,9)
Inbuilt h.v. capacitance, pF 450 300 300 300 300
High-voltage block mass, kg 800 800 900 1200 1500
Voltage regulator block mass, kg 600 650 600 700 900
           

Note:  *At Customer option Set can be manufactured at another rated voltage.

 

 

          

         
UIV-450 kV set HV SF6 -block moving          
on test stand territory          
          block slope changing mechanism allows promptly
          adapt set to cealing height

 

                                  
MPU-2.16-01 control panel                
             UIV-450 kV set voltage regulator block
             with control panel

MPU-2.16-01 type microprocessor control panel provides manual and complete automated (by plan schedule, set up by means of it) set control:

Manual and automatic mode of operation. 16 digital inputs and outputs
Built-in digital voltmeter. Adjustment of the measuring channels scale factors.
Test procedure programming. High EMC degree.
Switching of rate of HV change Set current and voltage displaying during tests.
3 «True RMS» inputs. Built-in stopwatch.
Printer port for test report printout. High accuracy of the automatic HV setting.
Galvanic separation of the control and measuring circuits (1 kV). Temperature monitoring of HV source.

 


print version